EMI gaskets for data centers combine environmental sealing with shielding against electromagnetic interference (EMI), electronic noise or crosstalk that’s caused by power lines, uninterruptible power systems (UPS), or nearby equipment. If server racks and cabinets lack EMI shielding, problems such as hardware malfunctions, system failures, and data corruption may result.

Elasto Proxy makes custom EMI gaskets for data centers. We specialize in low to medium volumes and use water jet cutting to fabricate electrically conductive silicones that are flame retardant, MIL-DTL-83528 QPL certified, or available in low durometers. Elasto Proxy also supplies molded EMI gaskets and can apply a conductive pressure-sensitive adhesive (PSA) to help speed installation.  

Keep reading to lean more and ask Elasto Proxy for EMI gaskets that support data center operations.

data center fire protection
Flame retardant EMI gaskets are made of shielding silicones with a UL94V0 flame rating.

Flame Retardant EMI Gaskets for Data Centers

Data centers face a risk of fire because of their high concentration of electrical equipment. In addition to reviewing fire suppression and mitigation plans, data center operators need to harden their facilities against damage. As part of these efforts, facilities managers may require data center construction companies to install fire-resistant gaskets with doors and panels.      

Flame retardant EMI gaskets are made of electrically conductive silicones with UL 94V0 flame ratings. They contain nickel-graphite particles and can be used in place of GORE GS2100 and GORE GS5200, EMI gasket materials that W.L. Gore discontinued in 2020. Nickel-graphite silicones cost less than silver-filled elastomers and provide proven levels of EMI shielding.

Flame Rated EMI Shielding Materials

Flame Rating

Elasto Proxy Material

Short Description

Compare to

 

UL 94 V0

EMI502-40-V0

40-durometer
Nickel-graphite
Silicone

GORE GS2100

 

UL 94 V0

EMI502-60-V0

65-durometer
Nickel-graphite
Silicone

GORE GS5200

 

military data center
The U.S. military is deploying modular data centers.

MIL-DTL-83528 EMI Gaskets for Data Centers

The U.S. military is building data centers to enable faster and more secure communications. Because these facilities house military electronics, they may require EMI gaskets that meet the lettered requirements of MIL-DTL-83528, a U.S. military detail specification that is sometimes written as MIL-G-83528 or M83528.

The MIL-G-83528 EMI gaskets that Elasto Proxy fabricates are made of elastomers that belong to the M83528 Qualified Product List (QPL). The Defense Logistics Agency (DLA), part of the U.S. Department of Defense (DoD), maintains this approved products list. As the table below shows, our M83528 gasket materials provide alternatives or offsets to Parker Chomerics CHO-SEAL® products.

MIL-DTL-83528 EMI Shielding Materials

MIL-DTL-83528

Elasto Proxy Material

Key Specifications

Compare to

Type A

EMI2569-65

65-durometer
Silver-copper
Silicone

CHO-SEAL 1215

Type B

EMI2368-65

65-durometer
Silver-copper

Silicone

Low outgassing

CHO-SEAL 1285

Type C

EMI2573-75

65-duromer

Silver-aluminum

Silicone

CHO-SEAL 1287

Type D

EMI2468-70

75-durometer

Silver-copper

Fluorosilicone

CHO-SEAL 1298

Type D

EMI2571-85

70-durometer
Silver-aluminum

Silicone

CHO-SEAL 1212

 

data center gasket
Soft EMI gaskets can “bounce back” once a compressive force, such as a closed door, is released.

Soft EMI Gaskets for Data Centers

Soft EMI gaskets for data centers provide reliable sealing under low closure force and are available in durometers as low as 30 Shore A. Elasto Proxy offers several nickel-graphite filled silicones, including a flame-retardant offset to GORE GS2100, and a 45-durometer silver-aluminum fluorosilicone that provides enhanced chemical resistance.  

Soft EMI Gasket Materials

Elasto Proxy Material

Short Description

Notes

EMI502-30

30-durometer
Nickel-graphite
Silicone

Compare to CHO-SEAL S6305, 6330, 6370, 6371,6372, and 6308

EMI502-40

40-durometer
Nickel-graphite
Silicone

EMI502-40-V0

40-durometer
Nickel-graphite
Silicone

UL 94V0
Compare to Gore GS2100

EMI550-45

45-durometer
Silver-aluminum
Fluorosilicone

 

Find EMI Gaskets for Data Centers

Do you need EMI gaskets for data centers? Whether it’s for military or civilian applications, Elasto Proxy can provide the EMI shielding that you need, and in lower minimum order quantities (MOQs) than you’ll find elsewhere.

Leave a Reply